Posts

Showing posts from April 27, 2020

DEAERATOR IN THERMAL POWER PLANT

Image
DEAERATOR IN THERMAL POWER PLANT  TABLE OF CONTENT  1:- Deaerator in thermal power plant 2:- Reason for use 3:- Deaerator working principle 4:- Working process  5:- Types of deaerator 6:- Condition must be fulfilled for successfull operation of the deaerator 7:- Causes to increase concentration of oxygen and carbon dioxide  8:- Some importan point related to deaerator DEAERATORS IN A THERMAL POWER PLANT 1:- Deaerators is a large, insulated tank, pressure vessels. 2:- One type of feed water heater is a contact type open heater. 3:- Purpose of deaerating the feed water (removal of carbon dioxide and oxygen from feed water). 4:- Mechanical deaeration is coupled with other external treatment aspects (chemical process), it provides the highest quality feed water for boiler use. 5:- Raise the temperature of the water (heating cold water to protect the boiler from thermal shock and prolong the boiler life). 6:- Economizing overall operation with stro