NORMS FOR EMISSION OF SOx, NOx, SPM & MERCURY FROM THERMAL POWER PLANTS
- The
notification from MoEF & CC dated 7th December-2015 amends existing norms related to emission of SPM and introduces new norms for emission of SO2, NOx
and Mercury from Thermal Power Plants (TPPs).
- It also
specifies modified limits for specific water consumption by TPPs.
- To convert
existing once through based condenser cooling system to recirculation type.
- Different
limits are specified based on capacity of power plant and year of installation.
NEW
REGULATIONS ON EMISSION
A summary of new regulations on air emission is
given in below:
Date of
Installation
PM
SO2
Nox
Mercury (Hg)
Before
31-12 -2003
100 mg/Nm3
600 mg/Nm3 for <500MW
600 mg/Nm3
0.03 mg/Nm3 for >=500MW
200 mg/Nm3 for >=500MW
After 01-01-2003 & Upto
31-12-2016
50 mg/Nm3
600 mg/Nm3 for <500 MW
300 mg/Nm3
0.03 mg/Nm3 for >=500MW
200 mg/Nm3 for >=500MW
0.03 mg/Nm3
On or after 01-01-2017
30 mg/Nm3
100 mg/Nm3
100 mg/Nm3
0.03 mg/Nm3
NEW REGULATION ON WATER USE
All plants with Once through Cooling (OTC) shall install
Cooling Tower (CT) and achieve specific water consumption up to maximum of 3.5
m3 /MWh within a period of two years from the date of publication of
notification.
All existing CT-based plants reduce specific water
consumption up to maximum of 3.5 m3 /MWh within a period of two years from the
date of publication of notification.
New plants to be installed after 1st January 2017 shall have
to meet specific water consumption up to maximum of 2.5 m3 /MWh and achieve
zero waste water discharged.
MOEF & CC HAS
SUBSEQUENTLY ISSUED AN AMENDMENT DATED 28 TH JUNE 2018 FOR STACK HEIGHT POST
FGD AND WATER CONSUMPTION WHICH IS MENTIONED BELOW:
INDUSTRY
PARAMETER
STANDARDS
TPS with FGD
stack height /limit in meters
Power Generation capacity :
100 MW and above
H = 6.902 (QX0.277)0.555
Or
100 m Whichever is more
Less than 100 MW H = 6.902 (QX0.277)0.555 Or 30 m
Whichever is more
Q = Emission rate of SO2 in kg/hr*
H = Physical stack height in meter
*Total of the all units connected to stack
Note: These standards shall apply to coal /lignite based Thermal Power Plant.
- All monitored values for SO2 and NOx
shall be corrected to 6% Oxygen, on dry basis.
- Specific water consumption shall not
exceed maximum of 3.0 m3/MWh for new plants installed after the 1st January
2017 and these plants shall also achieve zero waste water discharge.
- Seawater
based plants are exempted from conversion of once through to Cooling Tower
based system
- The notification from MoEF & CC dated 7th December-2015 amends existing norms related to emission of SPM and introduces new norms for emission of SO2, NOx and Mercury from Thermal Power Plants (TPPs).
- It also specifies modified limits for specific water consumption by TPPs.
- To convert existing once through based condenser cooling system to recirculation type.
- Different limits are specified based on capacity of power plant and year of installation.
Date of |
PM |
SO2 |
Nox |
Mercury (Hg) |
Before |
100 mg/Nm3 |
600 mg/Nm3 for <500MW |
600 mg/Nm3 |
0.03 mg/Nm3 for >=500MW |
200 mg/Nm3 for >=500MW |
||||
After 01-01-2003 & Upto
31-12-2016 |
50 mg/Nm3 |
600 mg/Nm3 for <500 MW |
300 mg/Nm3 |
0.03 mg/Nm3 for >=500MW |
200 mg/Nm3 for >=500MW |
0.03 mg/Nm3 |
|||
On or after 01-01-2017 |
30 mg/Nm3 |
100 mg/Nm3 |
100 mg/Nm3 |
0.03 mg/Nm3 |
All existing CT-based plants reduce specific water consumption up to maximum of 3.5 m3 /MWh within a period of two years from the date of publication of notification.
New plants to be installed after 1st January 2017 shall have to meet specific water consumption up to maximum of 2.5 m3 /MWh and achieve zero waste water discharged.
MOEF & CC HAS SUBSEQUENTLY ISSUED AN AMENDMENT DATED 28 TH JUNE 2018 FOR STACK HEIGHT POST FGD AND WATER CONSUMPTION WHICH IS MENTIONED BELOW:
INDUSTRY |
PARAMETER |
STANDARDS |
TPS with FGD |
stack height /limit in meters
|
Power Generation capacity :
100 MW and above |
Less than 100 MW H = 6.902 (QX0.277)0.555 Or 30 m Whichever is more |
||
Q = Emission rate of SO2 in kg/hr* H = Physical stack height in meter *Total of the all units connected to stack Note: These standards shall apply to coal /lignite based Thermal Power Plant. |
- All monitored values for SO2 and NOx shall be corrected to 6% Oxygen, on dry basis.
- Specific water consumption shall not exceed maximum of 3.0 m3/MWh for new plants installed after the 1st January 2017 and these plants shall also achieve zero waste water discharge.
- Seawater based plants are exempted from conversion of once through to Cooling Tower based system
The SO2 reduction
technology shall be done considering following factors:
1: Sulphur Content in Coal.
2: SO2 removal Efficiency requirement of particular plant.
3: Availability of Reagent (if Any).
4: Disposal and handling of By-product.
5: Locational/Geographical factors of the plant.
6: Plant life.
7: Space requirement for FGD facility
AUXILIARY POWER
CONSUMPTION for FGD:
Auxiliary Power Consumption (APC) is estimated to be
maximum 1% for FGD operations. In case GGH (Gas to Gas Heater) is used maximum
0.3% additional APC may be required.
The SO2 reduction
technology shall be done considering following factors:
1: Sulphur Content in Coal.
2: SO2 removal Efficiency requirement of particular plant.
3: Availability of Reagent (if Any).
4: Disposal and handling of By-product.
5: Locational/Geographical factors of the plant.
6: Plant life.
7: Space requirement for FGD facility
AUXILIARY POWER
CONSUMPTION for FGD:
Auxiliary Power Consumption (APC) is estimated to be
maximum 1% for FGD operations. In case GGH (Gas to Gas Heater) is used maximum
0.3% additional APC may be required.